OSHA SearchOSHA records by employer

AG Siding Services, LLC: OSHA inspections and violations

Marriottsville, Maryland · Siding Contractors · NAICS 238170

1inspections
7citation items
$1,312current penalties
Aug 28, 2023last inspection

OSHA has inspected AG Siding Services, LLC once in Maryland.

The inspection began on Aug 28, 2023 as a planned inspection, in Marriottsville.

That inspection ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $1,312 and still stand at $1,312.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and AG Siding Services, LLC averages $1,312 (1 cited inspection).

AG Siding Services, LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch AG Siding Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346942279 OPENED AUG 28, 2023Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 28, 2024

11441 Starlight Place, Marriottsville, MD 21104 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$312$312Oct 12, 2023Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,000$1,000Oct 12, 2023Final
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 12, 2023Final
Citation 1, item 2c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Oct 12, 2023Final
Citation 1, item 2d
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Oct 12, 2023Final
Citation 1, item 2e
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 12, 2023Final
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Oct 12, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other siding contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.