OSHA SearchOSHA records by employer

Aguila Construction: OSHA inspections and violations

Casper, Wyoming · Roofing Contractors · NAICS 238160

2inspections
14citation items
$11,200current penalties
Feb 16, 2017last inspection

Since 2016, OSHA inspectors have visited Aguila Construction in Wyoming 2 times.

The most recent inspection opened on Feb 16, 2017 as part of a related case, in Mills.

In all, OSHA issued 14 citation items: 11 serious and 3 other-than-serious.

The penalties, $11,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Aguila Construction averages $5,600 across 2 cited inspections.

Aguila Construction: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Aguila Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342111747 OPENED FEB 16, 2017Closed

Programmed related · Partial · Safety · 6 employees at the site · Closed May 3, 2023

6132 Thunder Valley Road, Mills, WY 82604 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$1,200$1,200Apr 6, 2017Final
Citation 1, item 2a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$2,000$2,000Apr 6, 2017Final
Citation 1, item 2b
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$0$0Apr 6, 2017Final
Citation 1, item 2c
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Apr 6, 2017Final
Citation 1, item 3a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,000$2,000Apr 6, 2017Final
Citation 1, item 3b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Apr 6, 2017Final
Citation 2, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Apr 6, 2017Final
Citation 2, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Apr 6, 2017Final

Inspection 341840528 OPENED OCT 10, 2016Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 2, 2023

1341 Harmony Road, Casper, WY 82601 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$2,000$2,000Oct 24, 2016Final
Citation 1, item 2
29 CFR 1926.502(d)(21) · Fall protection systems
Serious$2,000$2,000Oct 24, 2016Final
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$2,000Oct 24, 2016Final
Citation 1, item 3b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Oct 24, 2016Final
Citation 1, item 3c
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$0$0Oct 24, 2016Final
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Oct 24, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.