OSHA SearchOSHA records by employer

Air Masters LLC: OSHA inspections and violations

Port Saint Lucie, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
2citation items
$2,679current penalties
Sep 21, 2023last inspection

Air Masters LLC has one OSHA inspection on record in Florida.

OSHA opened it on Sep 21, 2023 as a planned inspection, in Port Saint Lucie.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $4,465 in penalties. After settlements and reviews the total is $2,679, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Air Masters LLC averages $2,679 over 1 cited inspection in that time.

Air Masters LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

333employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Air Masters LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346987571 OPENED SEP 21, 2023Closed

Planned · Partial · Safety · 12 employees at the site · Closed Feb 9, 2024

8560 Us Hwy 1, Port Saint Lucie, FL 34983 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$4,465$2,679Oct 5, 2023Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 5, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other plumbing, heating, and air-conditioning contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.