OSHA SearchOSHA records by employer

Airco Service Inc.: OSHA inspections and violations

Tulsa, Oklahoma · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

8inspections
9citation items
$14,656current penalties
Jul 22, 2020last inspection

Airco Service Inc. has 8 OSHA inspections on record in Oklahoma, the first in 1990.

OSHA's last visit started on Jul 22, 2020 on a referral, in Tulsa.

Across those inspections OSHA issued 9 citation items: 7 serious and 2 other-than-serious.

OSHA proposed $26,260 in penalties. After settlements and reviews the total is $14,656, down 44%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Airco Service Inc. averages $7,711 over 1 cited inspection in that time.

3 inspections on this page followed a fatal incident.

Airco Service Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Airco Service Inc.: OSHA citation items per year, 1990 to 2020
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

52employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Airco Service Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344847108 OPENED JUL 22, 2020Closed

Referral · Partial · Safety · 271 employees at the site · Closed Feb 5, 2021

12514 S. Kenston Ave., Tulsa, OK 74137 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 20, 2020: Employee falls from ceiling joist resulting in concussion

At 2:20 p.m. on July 20, 2020, Employee #1 was installing an HVAC vent system in an attic space, standing on top of a 2x10 ceiling joist while securing the vent with cloth straps and applying insulation tape. During the installation, the ceiling joist split and broke, causing Employee #1 to fall approximately 10 feet. The employee sustained head, back, and neck trauma, resulting in a concussion. Emergency services transported him to the hospital, where he was admitted for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$7,711$7,711Nov 24, 2020Final
Citation 1, item 2b
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$9,639$0Nov 24, 2020Final

Inspection 342570819 OPENED AUG 21, 2017Closed

Unprogrammed other · Partial · Safety · 225 employees at the site · Closed Aug 23, 2017

5113 N Harrison Ave, Shawnee, OK 74804 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 336480785 OPENED SEP 20, 2012Closed

Planned · Complete · Safety · 157 employees at the site · Closed Sep 21, 2012

15400 N. Western Ave, Edmond, OK 73013 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314932369 OPENED APR 5, 2011Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Apr 5, 2011

3403 Se Washington Blvd, Bartlesville, OK 74006 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314930884 OPENED MAR 7, 2011Closed

Accident · Partial · Safety · 2 employees at the site · Closed Jun 14, 2011

800 E. Dallas, Tulsa, OK 74013 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Feb 9, 2011 (fatal): Employee is killed in fall through skylight

On February 9, 2011, an employee was on roof of customer's facility to repair HV AC unit. The employee stepped through a snow covered skylight, falling 15 feet 2 .5 inches to the concrete floor below. The employee was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(4) · Guarding floor and wall openings and holes
Serious$4,900$3,430May 26, 2011Closed

Inspection 308068683 OPENED JAN 31, 2006Closed

Follow-up · Partial · Safety · 60 employees at the site · Closed Feb 2, 2006

6828 S. 77th East Ave, Tulsa, OK 74133 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308066091 OPENED SEP 15, 2005Closed

Accident · Partial · Safety · 60 employees at the site · Closed Feb 22, 2006

6828 S. 77th East Ave, Tulsa, OK 74133 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 14, 2005 (fatal): Employee is killed from a fall from roof

At approximately 1:15 p.m., on September 14, 2005, Employee #1 and a coworker we re installing a roof vent in a metal building housing an air-make-up heater. The heater was on the roof of an existing plant building, about 20 ft above the gro und. The building was surrounded by warehouses. An apprentice employee returned to the company truck to get a drill bit. The journeyman, Employee #1, decided to step onto the south warehouse roof and then onto the west warehouse roof, which was at the same height as the new smaller building housing the make-up heater. While he was on the warehouse roof, Employee #1 did not recognize that the roof had rows of built-in fiberglass skylights. He stepped on a skylight panel, the p anel broke, and the employee fell about 25 ft to a concrete floor. He died of in juries sustained in the fall.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$2,500$2,500Nov 7, 2005Closed

Inspection 106654841 OPENED JUL 25, 1990Closed

Accident · Partial · Safety · 17 employees at the site · Closed Oct 17, 1990

3754 E. 47th Street, Tulsa, OK 74135 · OSHA's record · Phone and website on Google Maps

Incident on Jun 14, 1990 (fatal): Electric shock - direct contact with energized parts

A JOURNEYMAN HEATING AND AIR CONDITIONING MECHANIC WAS WORKING ALONE, REPAIRING A RESIDENTIAL CENTRAL HEATING AND AIR CONDITIONING UNIT. AFTER COMPLETING REPAIR S ON THE UNIT AND REENERGIZING THE EQUIPMENT, THE EMPLOYEE WAS WORKING AT THE EX TERIOR FAN AND CONDENSING COIL. HE CONTACTED EXPOSED ENERGIZED CIRCUIT PARTS WIT H HIS LEFT HAND AND WAS ELECTROCUTED.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$810$565Aug 24, 1990Closed
Citation 1, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$250$125Aug 24, 1990Closed
Citation 1, item 3
29 CFR 1910.1200(h) · Hazard communication
Serious$250$125Aug 24, 1990Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Aug 24, 1990Closed
Citation 2, item 2
29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries
Other-than-serious$200$200Aug 24, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Tulsa site logged 3 recordable injuries or illnesses among about 398 workers: 28.5 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Airco Tulsa
Tulsa · 2025
398 3028.51.8
Airco Edmond
Edmond · 2025
82 000.01.8

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Sep 19, 2017, Shawnee: Hospitalization · fractures · multiple body parts, n.e.c.

Two employees were in a scissor lift approximately 17 to 18 feet high to hang duct work. They had finished hanging a piece when the scissor lift activated, began moving quickly in circles, and overturned. One of the employees was hospitalized with vertebrae, wrist, and ankle fractures. Both employees were tied off in the scissor lift at the time of the incident.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1926.501 · Fall protection in construction

Other plumbing, heating, and air-conditioning contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.