Airco Service Inc. has 8 OSHA inspections on record in Oklahoma, the first in 1990.
OSHA's last visit started on Jul 22, 2020 on a referral, in Tulsa.
Across those inspections OSHA issued 9 citation items: 7 serious and 2 other-than-serious.
OSHA proposed $26,260 in penalties. After settlements and reviews the total is $14,656, down 44%.
Most often, OSHA cited 1926.501, fall protection in construction (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Airco Service Inc. averages $7,711 over 1 cited inspection in that time.
3 inspections on this page followed a fatal incident.
Airco Service Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Oklahoma · latest 90 days of OSHA records
52employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.
Incident on Jul 20, 2020: Employee falls from ceiling joist resulting in concussion
At 2:20 p.m. on July 20, 2020, Employee #1 was installing an HVAC vent system in an attic space, standing on top of a 2x10 ceiling joist while securing the vent with cloth straps and applying insulation tape. During the installation, the ceiling joist split and broke, causing Employee #1 to fall approximately 10 feet. The employee sustained head, back, and neck trauma, resulting in a concussion. Emergency services transported him to the hospital, where he was admitted for treatment.
Accident · Partial · Safety · 2 employees at the site · Closed Jun 14, 2011
800 E. Dallas, Tulsa, OK 74013 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on Feb 9, 2011 (fatal): Employee is killed in fall through skylight
On February 9, 2011, an employee was on roof of customer's facility to repair HV AC unit. The employee stepped through a snow covered skylight, falling 15 feet 2 .5 inches to the concrete floor below. The employee was killed.
Incident on Sep 14, 2005 (fatal): Employee is killed from a fall from roof
At approximately 1:15 p.m., on September 14, 2005, Employee #1 and a coworker we re installing a roof vent in a metal building housing an air-make-up heater. The heater was on the roof of an existing plant building, about 20 ft above the gro und. The building was surrounded by warehouses. An apprentice employee returned to the company truck to get a drill bit. The journeyman, Employee #1, decided to step onto the south warehouse roof and then onto the west warehouse roof, which was at the same height as the new smaller building housing the make-up heater. While he was on the warehouse roof, Employee #1 did not recognize that the roof had rows of built-in fiberglass skylights. He stepped on a skylight panel, the p anel broke, and the employee fell about 25 ft to a concrete floor. He died of in juries sustained in the fall.
Incident on Jun 14, 1990 (fatal): Electric shock - direct contact with energized parts
A JOURNEYMAN HEATING AND AIR CONDITIONING MECHANIC WAS WORKING ALONE, REPAIRING A RESIDENTIAL CENTRAL HEATING AND AIR CONDITIONING UNIT. AFTER COMPLETING REPAIR S ON THE UNIT AND REENERGIZING THE EQUIPMENT, THE EMPLOYEE WAS WORKING AT THE EX TERIOR FAN AND CONDENSING COIL. HE CONTACTED EXPOSED ENERGIZED CIRCUIT PARTS WIT H HIS LEFT HAND AND WAS ELECTROCUTED.
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious
$0
$0
Aug 24, 1990
Closed
Citation 2, item 2
29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries
Other-than-serious
$200
$200
Aug 24, 1990
Closed
Injury and illness logs
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Tulsa site logged 3 recordable injuries or illnesses among about 398 workers: 28.5 per 100 full-time workers, against a median of 1.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Airco Tulsa
Tulsa · 2025
398
3
0
28.5
1.8
Airco Edmond
Edmond · 2025
82
0
0
0.0
1.8
Severe injury reports
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Two employees were in a scissor lift approximately 17 to 18 feet high to hang duct work. They had finished hanging a piece when the scissor lift activated, began moving quickly in circles, and overturned. One of the employees was hospitalized with vertebrae, wrist, and ankle fractures. Both employees were tied off in the scissor lift at the time of the incident.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.2 · Partial exemption for establishments in certain industries
29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.1200(h)
(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.23 · Guarding floor and wall openings and holes
Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.