Cordele, Georgia · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415
1inspections
1citation items
$9,282current penalties
Jun 5, 2019last inspection
Airxcel, Inc. has one OSHA inspection on record in Georgia.
OSHA opened it on Jun 5, 2019 on a referral, in Cordele.
From that inspection OSHA issued 1 citation item: 1 serious.
OSHA proposed $13,260 in penalties. After settlements and reviews the total is $9,282, down 30%.
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Airxcel, Inc. averages $9,282 over 1 cited inspection in that time.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Georgia · latest 90 days of OSHA records
142employers cited
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
OSHA records show Airxcel, Inc. at 3 sites in 3 states. Together they've had 20 inspections and $45,491 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Referral · Partial · Safety · 346 employees at the site · Closed Dec 19, 2019
156 Seedling Drive, Cordele, GA 31015 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jun 1, 2019: Employee partially amputates fingers while operating press b
At 10:30 p.m. on June 1, 2019, an employee was bending parts on a Cincinnati Press Brake, serial number 51796. The employee was adjusting the preset angles on the computer screen. While focused on the screen, the employee didn't realize that his left hand was between the dies of the machine. The employee's foot remained on the foot pedal while completing this process step. The employee leaned forward and activated the machine by depressing the pedal, which caused his ring and middle finger to be pinched between the dies at the point of operation. The employee suffered partial amputation of his left middle and ring fingers.
An employee was operating a press brake and partially amputated the left middle and ring fingers.
Sep 11, 2018, Cordele: Hospitalization · chemical burns and corrosions, unspecified · back, including spine, spinal cord, unspecified
An employee was pushing an air conditioner on an assembly line when he bumped a valve with his right shoulder. The valve then opened and sprayed refrigerant onto his right back area, causing chemical burns.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Georgia
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.