OSHA SearchOSHA records by employer

AJ Iron Erectors, Inc: OSHA inspections and violations

Chelmsford, Massachusetts · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
2citation items
$7,760current penalties
Mar 19, 2018last inspection

AJ Iron Erectors, Inc has one OSHA inspection on record in Massachusetts.

OSHA opened it on Mar 19, 2018, in Chelmsford.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,760 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. AJ Iron Erectors, Inc averages $7,760 over 1 cited inspection in that time.

AJ Iron Erectors, Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

260employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch AJ Iron Erectors, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343026019 OPENED MAR 19, 2018Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Mar 28, 2023

5 Courthouse Ln., Chelmsford, MA 01824 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 19, 2018: Employee falls through drop ceiling and breaks arm

At 12:00 p.m. on March 19, 2018, Employee #1, employed by a steel erection company, was working at a multiemployer construction project, the renovation of a two-story building. He was creating a work platform by adding wood planks to a false/drop ceiling when he fell through the ceiling, a fall height of 21 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was hospitalized and treated for a fractured right arm.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$3,880$3,880Jun 12, 2018Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,880$3,880Jun 12, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(4)

(4) Any part of a scaffold damaged or weakened such that its strength is less than that required by paragraph (a) of this section shall be immediately repaired or replaced, braced to meet those provisions, or removed from service until repaired.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other structural steel and precast concrete contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.