Alamos Masonry LLC: OSHA inspections and violations

Suwanee, Georgia · Masonry Contractors · NAICS 238140

1inspections
3citation items
$10,720current penalties
Jul 21, 2020last inspection

OSHA inspectors have visited Alamos Masonry LLC in Georgia one time.

It opened on Jul 21, 2020 after a fatality or catastrophe, in Suwanee and is still open.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $17,867; today they stand at $10,720, 40% less.

The rule cited most here is 1926.452 (rules for each type of scaffold), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Alamos Masonry LLC averages $10,720 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Alamos Masonry LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

145employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Alamos Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344843883 OPENED JUL 21, 2020Open

Fatality or catastrophe · Complete · Safety · 6 employees at the site · Open

1083 Old Peachtree Road, Suwanee, GA 30024 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 21, 2020 (fatal): Employee is killed in fall from scaffold while working to pu

At 3:30 p.m. on July 21, 2020, an employee was working from a scaffold to pump concrete mix into a block wall. At some point, the employee lost his balance and fell from the scaffold while setting up the hose to pump the concrete. The employee was killed by blunt force trauma to unspecified body parts.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$13,494$8,421Jan 8, 2021Final
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$4,048$2,299Jan 8, 2021Final
Citation 2, item 1
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Other-than-serious$325$0Jan 8, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

29 CFR 1926.452(c)(4)

(4) Where uplift can occur which would displace scaffold end frames or panels, the frames or panels shall be locked together vertically by pins or equivalent means.

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.