OSHA SearchOSHA records by employer

Aldo U.S. Inc.: OSHA inspections and violations

Glendale, Wisconsin · Shoe Stores · NAICS 448210

1inspections
3citation items
$4,000current penalties
Feb 2, 2016last inspection

Aldo U.S. Inc. has one OSHA inspection on record in Wisconsin.

OSHA opened it on Feb 2, 2016 after a complaint, in Glendale.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $4,000 in penalties and the amount has not been reduced.

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Aldo U.S. Inc. averages $4,000 over 1 cited inspection in that time.

Aldo U.S. Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

223employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Aldo U.S. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Aldo U.S. Inc. at 2 sites in 2 states. Together they've had 2 inspections and $5,355 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 341221182 OPENED FEB 2, 2016Closed

Complaint · Partial · Health · 9 employees at the site · Closed Jun 27, 2016

5790 Bayshore Drive Apt #q118, Glendale, WI 53217 · Shoe Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$4,000$4,000Mar 28, 2016Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Mar 28, 2016Final
Citation 2, item 2
29 CFR 1910.37(b)(6) · Exit routes
Other-than-serious$0$0Mar 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(b)(6)

(6) Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m 2) are permitted.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.