OSHA SearchOSHA records by employer

Aleandra Guado: OSHA inspections and violations

Winston Salem, North Carolina · Framing Contractors · NAICS 238130

1inspections
4citation items
$1,950current penalties
Aug 30, 2017last inspection

OSHA has inspected Aleandra Guado once in North Carolina.

The inspection began on Aug 30, 2017 on a referral, in Winston Salem.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $1,950 and still stand at $1,950.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Aleandra Guado averages $1,950 (1 cited inspection).

Aleandra Guado: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

51 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Aleandra Guado and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342603495 OPENED AUG 30, 2017Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jan 26, 2018

136 Wallburg Fields Lot 11, Winston Salem, NC 27107 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.306(b)(3)(i) · Air receivers
Serious$450$450Sep 8, 2017Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500Sep 8, 2017Final
Citation 1, item 2b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Sep 8, 2017Final
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Sep 8, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.306 · Air receivers

29 CFR 1926.306(b)(3)(i)

(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.