Alejandro Gonzalez: OSHA inspections and violations

Katy, Texas · Roofing Contractors · NAICS 238160

2inspections
4citation items
$5,810current penalties
Sep 11, 2019last inspection

OSHA has inspected Alejandro Gonzalez 2 times in Texas since 2012.

The latest one began on Sep 11, 2019 as a planned inspection, in Katy.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $10,484 and now stand at $5,810, 45% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Alejandro Gonzalez averages $3,410 (1 cited inspection).

Alejandro Gonzalez: OSHA citation items per year, 2012 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Alejandro Gonzalez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344301221 OPENED SEP 11, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 15, 2022

24038 Prairie Glen Ln., Katy, TX 77493 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,842$1,705Sep 24, 2019Final
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,842$1,705Sep 24, 2019Final

Inspection 334504735 OPENED MAY 29, 2012Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 6, 2016

26310 Langdon Ct, Katy, TX 77493 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,400Jun 6, 2012Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,000Jun 6, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.