OSHA SearchOSHA records by employer

Alfredo Martinez: OSHA inspections and violations

San Antonio, Texas · Roofing Contractors · NAICS 238160

5inspections
8citation items
$42,643current penalties
Jun 6, 2024last inspection

OSHA has inspected Alfredo Martinez 5 times in Texas since 2011.

The latest one began on Jun 6, 2024 as a planned inspection, in San Antonio; the case is still open.

Those inspections ended with 8 citation items: 7 serious and 1 willful.

Penalties were first proposed at $47,143 and now stand at $42,643, 10% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 4 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Alfredo Martinez averages $16,132 (2 cited inspections).

Alfredo Martinez: OSHA citation items per year, 2011 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Alfredo Martinez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347535908 OPENED JUN 6, 2024Open

Planned · Partial · Safety · 9 employees at the site · Open

15307 Comanche Place, San Antonio, TX 78233 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,148$4,148Sep 16, 2024Final
Citation 1, item 2
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$2,765$2,765Sep 16, 2024Final

Inspection 342401718 OPENED JUN 15, 2017Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Jul 26, 2017

8712 Old Manor Rd., Austin, TX 78724 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342191806 OPENED MAR 22, 2017Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 10, 2023

8712 Old Manor Rd., Austin, TX 78724 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Willful$25,350$25,350May 15, 2017Final

Inspection 315630186 OPENED JAN 27, 2012Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 14, 2013

8707 Lakeside Prwy, San Antonio, TX 78235 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,940$2,940Mar 28, 2012Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,940$2,940Mar 28, 2012Closed

Inspection 314185224 OPENED OCT 17, 2011Closed

Planned · Partial · Safety · 6 employees at the site · Closed Mar 14, 2014

2221 Yaupon Drive, Irving, TX 75063 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,400$1,200Oct 26, 2011Closed
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$4,200$2,100Oct 26, 2011Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,400$1,200Oct 26, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.