Inspection 342345295 OPENED MAY 24, 2017Closed
7000 Hwy 46, Paso Robles, CA 93446 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on May 9, 2017: Employee amputates finger while repairing hydraulic hose
At 1:10 p.m. on May 9, 2017, an employee, who was a mechanic, was assigned to repair a leaking hydraulic line on the front outrigger extender of a Grove mobile crane (model number: TM9120; serial 8number: 4732). After depressurizing and disconnecting the outrigger's hydraulic lines, a coworker operating a Gradall Telescopic forklift was on the passenger side of the outrigger to help hold it in place. The employee then removed a cover plate and locking pin, and was holding the hydraulic hoses out of the way with his right hand, when the outrigger beam shifted its position. The employee's right middle finger became pinned between the outrigger beam and a mounting plate, resulting in its amputation. The employee was hospitalized and received treatment. treatment.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 3203(B)(2) |
Other-than-serious | $275 | $275 | Aug 16, 2017 | Final |