OSHA SearchOSHA records by employer

All Decked Out Inc: OSHA inspections and violations

Saratoga, Utah · Framing Contractors · NAICS 238130

3inspections
5citation items
$7,000current penalties
May 31, 2019last inspection

OSHA has inspected All Decked Out Inc 3 times in Utah since 2013.

The latest one began on May 31, 2019 as a planned inspection, in Riverton.

Those inspections ended with 5 citation items: 4 serious and 1 repeat.

Penalties were first proposed at $7,000 and still stand at $7,000.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and All Decked Out Inc averages $1,500 (2 cited inspections).

All Decked Out Inc: OSHA citation items per year, 2013 to 2019
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch All Decked Out Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344078720 OPENED MAY 31, 2019Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jul 29, 2020

14200 S 2575 W, Riverton, UT 84065 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Jun 24, 2019Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Jun 24, 2019Final

Inspection 340839521 OPENED AUG 11, 2015Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 5, 2016

Nw Corner Of 8780 S And Okubo Dr, West Jordan, UT 84088 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$1,500$1,500Nov 12, 2015Final
Citation 1, item 1b
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$0$0Nov 12, 2015Final

Inspection 317410033 OPENED NOV 25, 2013Closed

Planned · Partial · Safety · 5 employees at the site · Closed Nov 20, 2014

4112 S Pelican Lane, Saratoga, UT 84043 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,000$4,000Jan 27, 2014Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.