OSHA SearchOSHA records by employer

All Temperature Service, Inc.: OSHA inspections and violations

Plantation, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
3citation items
$5,040current penalties
May 7, 2015last inspection

All Temperature Service, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on May 7, 2015, in Plantation.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $7,200 in penalties. After settlements and reviews the total is $5,040, down 30%.

Most often, OSHA cited 1926.1053, ladders in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. All Temperature Service, Inc. averages $5,040 over 1 cited inspection in that time.

All Temperature Service, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch All Temperature Service, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340613918 OPENED MAY 7, 2015Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Oct 28, 2016

1371 South University Drive, Plantation, FL 33324 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,600$1,120Sep 8, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,800$1,960Sep 8, 2015Final
Citation 1, item 3
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$2,800$1,960Sep 8, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.1053(b)(6)

(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other plumbing, heating, and air-conditioning contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.