OSHA SearchOSHA records by employer

All Type Construction, Inc.: OSHA inspections and violations

Cambridge, Massachusetts · Siding Contractors · NAICS 238170

1inspections
5citation items
$14,208current penalties
Jan 9, 2019last inspection

All Type Construction, Inc. has one OSHA inspection on record in Massachusetts.

OSHA opened it on Jan 9, 2019 after a complaint, in Cambridge.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $14,208 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. All Type Construction, Inc. averages $14,208 over 1 cited inspection in that time.

All Type Construction, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites All Type Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343700258 OPENED JAN 9, 2019Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Aug 20, 2019

229-235 Charles Street, Cambridge, MA 02139 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,273$2,273Jun 20, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,842$2,842Jun 20, 2019Final
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$3,978$3,978Jun 20, 2019Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,842$2,842Jun 20, 2019Final
Citation 1, item 5
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,273$2,273Jun 20, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other siding contractors employers in Massachusetts

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.