OSHA SearchOSHA records by employer

All-Valley Unit Step, Inc: OSHA inspections and violations

Harlingen, Texas · Other Concrete Product Manufacturing · NAICS 327390

3inspections
9citation items
$1,960current penalties
Apr 20, 2017last inspection

Since 1997, OSHA inspectors have visited All-Valley Unit Step, Inc in Texas 3 times.

The most recent inspection opened on Apr 20, 2017 as a planned inspection, in Harlingen.

In all, OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

The proposed penalties came to $11,016; today they stand at $1,960, 82% less.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. All-Valley Unit Step, Inc averages $980 across 2 cited inspections.

All-Valley Unit Step, Inc: OSHA citation items per year, 1997 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch All-Valley Unit Step, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342267218 OPENED APR 20, 2017Closed

Planned · Complete · Health · 4 employees at the site · Closed Dec 7, 2021

2102 North 77 Sunshine Strip, Harlingen, TX 78550 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$2,897$250Aug 1, 2017Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$2,173$250Aug 1, 2017Final
Citation 1, item 3a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$4,346$500Aug 1, 2017Final
Citation 1, item 3b
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Aug 1, 2017Final
Citation 1, item 3c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 1, 2017Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 1, 2017Final

Inspection 341142511 OPENED DEC 28, 2015Closed

Planned · Complete · Health · 4 employees at the site · Closed Mar 16, 2016

2102 North 77 Sunshine Strip, Harlingen, TX 78550 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c) · Respiratory protection
Serious$1,600$960Feb 10, 2016Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Feb 10, 2016Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Feb 10, 2016Final

Inspection 300190824 OPENED DEC 10, 1997Closed

Planned · No inspection · Health · Closed Dec 30, 1997

2102 Sunshine Strip, Harlingen, TX 78550 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)

(c) After completing the test exercises, the test administrator must question each test subject regarding the comfort of the respirator. When a test subject states that the respirator is unacceptable, the employer must ensure that the test administrator repeats the protocol using another respirator model.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other concrete product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.