OSHA SearchOSHA records by employer

Allco Electric Company, Inc.: OSHA inspections and violations

Fort Bragg, North Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

9inspections
10citation items
$3,325current penalties
Feb 21, 2018last inspection

Since 2006, OSHA inspectors have visited Allco Electric Company, Inc. in North Carolina 9 times.

The most recent inspection opened on Feb 21, 2018, in Rtp.

In all, OSHA issued 10 citation items: 6 serious and 4 other-than-serious.

The proposed penalties came to $5,000; today they stand at $3,325, 34% less.

The rule cited most here is 1926.405 (job-site wiring), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Allco Electric Company, Inc. averages $0 across 1 cited inspection.

Allco Electric Company, Inc.: OSHA citation items per year, 2006 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

226employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Allco Electric Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342973112 OPENED FEB 21, 2018Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Apr 9, 2018

3041 Cornwallis Road, Rtp, NC 27709 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Other-than-serious$0$0Mar 8, 2018Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Mar 8, 2018Final

Inspection 338900830 OPENED FEB 6, 2013Closed

Planned · Complete · Safety · 300 employees at the site · Closed Feb 7, 2013

Bldg E-2535 - 3866 Kuwait Street, Fort Bragg, NC 28310 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 338899834 OPENED FEB 5, 2013Closed

Planned · Complete · Safety · 275 employees at the site · Closed Jun 10, 2013

Building 2-1105 C Stack 2175 Reilly Rd Stop A, Fort Bragg, NC 28310 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$3,000$1,800Mar 8, 2013Final
Citation 1, item 1b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Mar 8, 2013Final
Citation 1, item 1c
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$0$0Mar 8, 2013Final
Citation 1, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Mar 8, 2013Final

Inspection 315959528 OPENED OCT 27, 2011Closed

Planned · Partial · Safety · 72 employees at the site · Closed Nov 9, 2011

Lenoir County Jail Addition, Kinston, NC 28501 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315450817 OPENED JUL 13, 2011Closed

Unprogrammed other · Partial · Safety · 90 employees at the site · Closed Sep 1, 2011

0284 Warren Dr., Winterville, NC 28590 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$1,250$1,000Jul 25, 2011Closed
Citation 1, item 1b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jul 25, 2011Closed

Inspection 311094486 OPENED JAN 6, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 7, 2010

Buildings # C-6018, C-5917, C-6015 And C-6117, Fort Bragg, NC 28310 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311093561 OPENED JAN 27, 2009Closed

Planned · Complete · Safety · 17 employees at the site · Closed Feb 26, 2009

4821 Crissy Street, Goldsboro, NC 27531 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311936389 OPENED APR 29, 2008Closed

Complaint · Partial · Health · 3 employees at the site · Closed Sep 26, 2008

651 N. Winstead Avenue, Rocky Mount, NC 27804 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$750$525Jun 9, 2008Closed
1 older inspection

Inspection 309739415 OPENED JAN 6, 2006Closed

Unprogrammed other · Complete · Safety · 80 employees at the site · Closed Jan 26, 2006

1986 Pitt Tech Road, Winterville, NC 28590 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(h)(1) · Accident prevention signs and tags
Other-than-serious$0$0Jan 13, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.200(h)(1)

(h) Accident prevention tags. (1) Accident prevention tags shall be used as a temporary means of warning employees of an existing hazard, such as defective tools, equipment, etc. They shall not be used in place of, or as a substitute for, accident prevention signs.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

Other electrical contractors and other wiring installation contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.