OSHA SearchOSHA records by employer

Allen Steel Erection Inc.: OSHA inspections and violations

Ocoee, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
11citation items
$20,526current penalties
Apr 14, 2022last inspection

Allen Steel Erection Inc. has 3 OSHA inspections on record in Florida, the first in 2006.

OSHA's last visit started on Apr 14, 2022 as part of a related case, in Orlando.

Across those inspections OSHA issued 11 citation items: 8 serious and 3 other-than-serious.

OSHA proposed $20,526 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.351, arc welding and cutting (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Allen Steel Erection Inc. averages $10,151 over 1 cited inspection in that time.

Allen Steel Erection Inc.: OSHA citation items per year, 2006 to 2022
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Allen Steel Erection Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345899496 OPENED APR 14, 2022Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Sep 27, 2026

5421 Diplomat Circle, Orlando, FL 32810 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(b)(3) · Fall protection
Serious$10,151$10,151Oct 6, 2022Final

Inspection 310027834 OPENED SEP 26, 2006Closed

Referral · Partial · Safety · 6 employees at the site · Closed Jan 12, 2016

7750 S Us Highway 1, Bunnell, FL 32110 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(2) · Arc welding and cutting
Serious$1,000$1,000Oct 31, 2006Closed
Citation 1, item 2
29 CFR 1926.351(b)(3) · Arc welding and cutting
Serious$1,000$1,000Oct 31, 2006Closed
Citation 1, item 3
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$1,000$1,000Oct 31, 2006Closed
Citation 1, item 4
29 CFR 1926.757(b)(3) · Open web steel joists
Serious$2,000$2,000Oct 31, 2006Closed
Citation 1, item 5
29 CFR 1926.757(e)(2) · Open web steel joists
Serious$2,000$2,000Oct 31, 2006Closed
Citation 1, item 6
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,000$2,000Oct 31, 2006Closed
Citation 2, item 1
29 CFR 1904.29(b)(3) · Injury and illness log
Other-than-serious$1,000$1,000Oct 31, 2006Closed

Inspection 310296512 OPENED JUL 19, 2006Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 1, 2007

9580 East Colonial Dr., Ocoee, FL 34761 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$375$375Aug 4, 2006Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Aug 4, 2006Closed
Citation 2, item 2
29 CFR 1926.350(a)(9) · Gas welding and cutting
Other-than-serious$0$0Aug 4, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(3)

(3) How quickly must each injury or illness be recorded? You must enter each recordable injury or illness on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness has occurred.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(9)

(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.351(b)(2)

(2) Only cable free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder is connected shall be used, except that cables with standard insulated connectors or with splices whose insulating quality is equal to that of the cable are permitted.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.59 · Hazard communication

29 CFR 1926.757 · Open web steel joists

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.