OSHA SearchOSHA records by employer

Alliance Construction and Design, Inc.: OSHA inspections and violations

Hilbert, Wisconsin · Industrial Building Construction · NAICS 236210

5inspections
8citation items
$22,108current penalties
Mar 2, 2023last inspection

OSHA has inspected Alliance Construction and Design, Inc. 5 times in Wisconsin since 2014.

The latest one began on Mar 2, 2023 as a planned inspection, in Appleton.

Those inspections ended with 8 citation items: 6 serious, 1 repeat and 1 other-than-serious.

Penalties were first proposed at $40,101 and now stand at $22,108, 45% lower after settlements or reviews.

Aerial lifts comes up most often in these citations: 3 items under 1926.453.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Alliance Construction and Design, Inc. averages $5,410 (3 cited inspections).

It reported 1 severe injury to OSHA since 2015.

Alliance Construction and Design, Inc.: OSHA citation items per year, 2014 to 2023
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

223employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Alliance Construction and Design, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346539224 OPENED MAR 2, 2023Closed

Planned · Partial · Safety · 46 employees at the site · Closed Jun 28, 2023

3860 W Wisconsin Ave, Appleton, WI 54914 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Repeat$15,627$7,814Mar 17, 2023Final
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Mar 17, 2023Final

Inspection 345381412 OPENED JUN 24, 2021Closed

Planned · Partial · Safety · 48 employees at the site · Closed Oct 19, 2021

S73 W16555 Janesville Road, Muskego, WI 53150 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,642$4,642Jul 30, 2021Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 30, 2021Final
Citation 1, item 1c
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,642$0Jul 30, 2021Final

Inspection 341409761 OPENED APR 19, 2016Closed

Referral · Partial · Safety · 33 employees at the site · Closed May 16, 2016

1180 Mid Valley Rd., De Pere, WI 54115 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.754(e)(5)(i) · Structural steel assembly
Serious$5,390$3,773Apr 28, 2016Final

Inspection 340113554 OPENED DEC 2, 2014Open

Planned · Complete · Safety · Open

117 S. Washington St., Green Bay, WI 54301 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 340106194 OPENED NOV 26, 2014Closed

Unprogrammed other · Partial · Safety · 32 employees at the site · Closed Jan 22, 2015

Progress Dr, Hilbert, WI 54129 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,900$2,450Dec 17, 2014Final
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$4,900$3,430Dec 17, 2014Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Apr 13, 2016, De Pere: Hospitalization · fractures · head and trunk

On 4/13/16, an employee slipped on metal decking and fell approximately 10 feet, suffering fractured ribs and a fractured skull.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.754 · Structural steel assembly

29 CFR 1926.760 · Fall protection

Other industrial building construction employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.