OSHA SearchOSHA records by employer

Alltech Electrical Contracting Corp.: OSHA inspections and violations

New York, New York · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
1citation items
$2,897current penalties
Mar 30, 2018last inspection

Alltech Electrical Contracting Corp. has 2 OSHA inspections on record in New York, the first in 2017.

OSHA's last visit started on Mar 30, 2018 to follow up on an earlier case, in New York.

Across those inspections OSHA issued 1 citation item: 1 serious.

OSHA proposed $2,897 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Alltech Electrical Contracting Corp. averages $2,897 over 1 cited inspection in that time.

Alltech Electrical Contracting Corp.: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

358employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Alltech Electrical Contracting Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343052585 OPENED MAR 30, 2018Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed May 4, 2018

350 Broadway, New York, NY 10003 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342353216 OPENED MAY 24, 2017Closed

Unprogrammed other · Complete · Safety · 11 employees at the site · Closed Jan 11, 2023

350 Broadway, New York, NY 10001 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$2,897$2,897Aug 4, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

Other electrical contractors and other wiring installation contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.