Alonso LLC: OSHA inspections and violations

Grimes, Iowa · Masonry Contractors · NAICS 238140

1inspections
5citation items
$15,625current penalties
Dec 5, 2024last inspection

Alonso LLC has one OSHA inspection on record in Iowa.

OSHA opened it on Dec 5, 2024 after a complaint, in Grimes.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $15,625 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.454, scaffold training (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Alonso LLC averages $15,625 over 1 cited inspection in that time.

Alonso LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

69employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Alonso LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347915902 OPENED DEC 5, 2024Closed

Complaint · Partial · Safety · 6 employees at the site · Closed May 4, 2026

701 Ne Gateway Drive, Grimes, IA 50111 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,125$3,125Feb 3, 2025Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,125$3,125Feb 3, 2025Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$3,125$3,125Feb 3, 2025Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$3,125$3,125Feb 3, 2025Final
Citation 1, item 5
29 CFR 1926.454(b) · Scaffold training
Serious$3,125$3,125Feb 3, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.