OSHA SearchOSHA records by employer

Alpha and Omega Construction: OSHA inspections and violations

Bethel Park, Pennsylvania · Framing Contractors · NAICS 238130

1inspections
4citation items
$3,880current penalties
Jul 24, 2018last inspection

OSHA has inspected Alpha and Omega Construction once in Pennsylvania.

The inspection began on Jul 24, 2018 as a planned inspection, in Bethel Park.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $3,880 and still stand at $3,880.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Alpha and Omega Construction averages $3,880 (1 cited inspection).

Alpha and Omega Construction: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Alpha and Omega Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343323622 OPENED JUL 24, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 5, 2023

100 Broughton Road, Bethel Park, PA 15102 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,663$1,663Aug 14, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Aug 14, 2018Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 14, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,217$2,217Aug 14, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.