OSHA SearchOSHA records by employer

AL's Electric Service: OSHA inspections and violations

Colchester, Vermont · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
4citation items
$1,000current penalties
Mar 9, 2016last inspection

OSHA has inspected AL's Electric Service 2 times in Vermont since 1992.

The latest one began on Mar 9, 2016, in Colchester.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $1,185 and now stand at $1,000, 16% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 3 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and AL's Electric Service averages $900 (1 cited inspection).

AL's Electric Service: OSHA citation items per year, 1992 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch AL's Electric Service and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341310258 OPENED MAR 9, 2016Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed May 16, 2016

34 Brooke Lane, Colchester, VT 05446 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$400$500Mar 24, 2016Final
Citation 1, item 2
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$560$400Mar 24, 2016Final

Inspection 111709846 OPENED AUG 11, 1992Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 28, 1993

128 Prim Rd, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$225$100Aug 31, 1992Closed
Citation 1, item 1b
29 CFR 1926.405(g)(1)(i) · Job-site wiring
Serious$0$0Aug 31, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.405(g)(1)(i)

(g) Flexible cords and cables—(1) Use of flexible cords and cables—(i) Permitted uses. Flexible cords and cables shall be suitable for conditions of use and location. Flexible cords and cables shall be used only for:

Other electrical contractors and other wiring installation contractors employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.