OSHA SearchOSHA records by employer

Alvarez Tunneling & Roofing Inc: OSHA inspections and violations

Corpus Christi, Texas · Other Heavy and Civil Engineering Construction · NAICS 237990

4inspections
8citation items
$39,908current penalties
Jul 6, 2023last inspection

Alvarez Tunneling & Roofing Inc has 4 OSHA inspections on record in Texas, the first in 2021.

OSHA's last visit started on Jul 6, 2023 to follow up on an earlier case, in Corpus Christi.

Across those inspections OSHA issued 8 citation items: 8 serious.

OSHA proposed $39,908 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.651, excavations (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Alvarez Tunneling & Roofing Inc averages $19,954 over 2 cited inspections in that time.

2 inspections on this page followed a fatal incident.

Alvarez Tunneling & Roofing Inc: OSHA citation items per year, 2021 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Alvarez Tunneling & Roofing Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346812944 OPENED JUL 6, 2023Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Dec 15, 2023

7017 Hathor Drive, Corpus Christi, TX 78412 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345896328 OPENED APR 13, 2022Closed

Fatality or catastrophe · Complete · Safety · 10 employees at the site · Closed Apr 28, 2026

7017 Hathor Dr, Corpus Christi, TX 78412 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Apr 13, 2022 (fatal): Two employees are killed when electrocuted

At 4:00 p.m. on April 13, 2022, two employees were performing excavation work under a residential home in preparation for plumbing work. They were electrocuted and killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$4,351$4,351Aug 3, 2022Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$4,351$4,351Aug 3, 2022Final

Inspection 345763288 OPENED JAN 31, 2022Closed

Follow-up · No inspection · Safety · 11 employees at the site · Closed Mar 2, 2022

8761 State Highway 44, Corpus Christi, TX 78406 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345163257 OPENED FEB 24, 2021Closed

Fatality or catastrophe · Complete · Safety · 15 employees at the site · Closed Sep 30, 2025

8761 State Highway 44, Corpus Christi, TX 78406 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Feb 23, 2021 (fatal): Employee is killed by asphyxia when tunnel collapses

At 12:11 p.m. on February 23, 2021, an employee worked to tunnel under the foundation of a building. At some point, the tunnel collapsed and engulfed the employee in soil. The employee was killed by asphyxia.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(b)(1) · Excavations
Serious$5,461$5,461Jul 8, 2021Final
Citation 1, item 2 Serious$5,461$5,461Jul 8, 2021Final
Citation 1, item 3 Serious$5,461$5,461Jul 8, 2021Final
Citation 1, item 4
29 CFR 1926.651(h)(1) · Excavations
Serious$5,461$5,461Jul 8, 2021Final
Citation 1, item 5 Serious$5,461$5,461Jul 8, 2021Final
Citation 1, item 6
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,901$3,901Jul 8, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(b)(1)

(b) Underground installations. (1) The estimated location of utility installations, such as sewer, telephone, fuel, electric, water lines, or any other underground installations that reasonably may be expected to be encountered during excavation work, shall be determined prior to opening an excavation.

29 CFR 1926.652 · Trench protection

Other other heavy and civil engineering construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.