OSHA SearchOSHA records by employer

American Air Filter Company, Inc.: OSHA inspections and violations

Fayetteville, Arkansas · Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers · NAICS 423730

5inspections
14citation items
$26,148current penalties
Jan 14, 2026last inspection

OSHA has inspected American Air Filter Company, Inc. 5 times in Arkansas since 1982.

The latest one began on Jan 14, 2026 after a complaint, in Fayetteville.

Those inspections ended with 14 citation items: 8 serious and 6 other-than-serious.

Penalties were first proposed at $40,785 and now stand at $26,148, 36% lower after settlements or reviews.

Machine guarding comes up most often in these citations: 4 items under 1910.212.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,424, and American Air Filter Company, Inc. averages $12,879 (2 cited inspections).

American Air Filter Company, Inc.: OSHA citation items per year, 1982 to 2026
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch American Air Filter Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348687344 OPENED JAN 14, 2026Closed

Complaint · Partial · Safety · 126 employees at the site · Closed Apr 28, 2026

2355 S Armstrong Ave, Fayetteville, AR 72701 · Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$8,040$4,824Mar 19, 2026Final

Inspection 343208906 OPENED JUN 5, 2018Closed

Complaint · Partial · Health · 118 employees at the site · Closed Dec 10, 2018

2355 S Armstrong Ave, Fayetteville, AR 72701 · Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1048(c)(1) · Formaldehyde
Serious$12,934$12,934Oct 25, 2018Final
Citation 1, item 1b
29 CFR 1910.1048(f)(1) · Formaldehyde
Serious$0$0Oct 25, 2018Final
Citation 1, item 3
29 CFR 1910.1048(j)(2) · Formaldehyde
Other-than-serious$12,934$5,000Oct 25, 2018Final
Citation 1, item 4a Serious$6,097$3,000Oct 25, 2018Final

Inspection 101794170 OPENED AUG 13, 1986Closed

Planned · Complete · Safety · 150 employees at the site · Closed Sep 22, 1986

2355 Armstrong Drive, Fayetteville, AR 72701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$240$120Sep 11, 1986Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$180$90Sep 11, 1986Closed
Citation 1, item 4
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Serious$180$90Sep 11, 1986Closed
Citation 2, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 11, 1986Closed
Citation 2, item 2
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 11, 1986Closed
Citation 2, item 4
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Sep 11, 1986Closed
Citation 2, item 5
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 11, 1986Closed

Inspection 16623845 OPENED MAY 11, 1983Closed

Planned · Complete · Safety · 129 employees at the site · Closed Jun 6, 1983

2355 Armstrong Ave, Fayetteville, AR 72701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$180$90Jun 6, 1983Closed
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0May 20, 1983Closed

Inspection 16599169 OPENED OCT 6, 1982Closed

Planned · Partial · Health · 150 employees at the site · Closed Oct 13, 1982

2355 Armstrong, Fayetteville, AR 72701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1048(c)(1)

(c) Permissible Exposure Limit (PEL)—(1) TWA: The employer shall assure that no employee is exposed to an airborne concentration of formaldehyde which exceeds 0.75 parts formaldehyde per million parts of air (0.75 ppm) as an 8-hour TWA.

29 CFR 1910.1048(f)(1)

(f) Methods of compliance—(1) Engineering controls and work practices. The employer shall institute engineering and work practice controls to reduce and maintain employee exposures to formaldehyde at or below the TWA and the STEL.

29 CFR 1910.1048(j)(2)

(2) In work areas where spillage may occur, the employer shall make provisions to contain the spill, to decontaminate the work area, and to dispose of the waste.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.