American Arches: OSHA inspections and violations

Houston, Texas · Engineered Wood Member (except Truss) Manufacturing · NAICS 321213

1inspections
3citation items
$1,735current penalties
Oct 27, 2020last inspection

OSHA inspectors have visited American Arches in Texas one time.

It opened on Oct 27, 2020 after a complaint, in Houston.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $2,892; today they stand at $1,735, 40% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. American Arches averages $1,735 across 1 cited inspection.

American Arches: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch American Arches and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344998174 OPENED OCT 27, 2020Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jan 4, 2021

11269 Windfern Rd, Suite B, Houston, TX 77064 · Engineered Wood Member (except Truss) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,892$1,735Dec 10, 2020Final
Citation 1, item 1b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Dec 10, 2020Final
Citation 2, item 1
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 10, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.305(g)(1)(iv)(a)

(A) As a substitute for the fixed wiring of a structure;

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

Other engineered wood member (except truss) manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.