OSHA SearchOSHA records by employer

American Cargo Group: OSHA inspections and violations

Ogden, Utah · Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing · NAICS 333924

2inspections
5citation items
$700current penalties
Jan 10, 2025last inspection

OSHA has inspected American Cargo Group 2 times in Utah since 2021.

The latest one began on Jan 10, 2025 after an accident, in Ogden.

Those inspections ended with 5 citation items: 1 serious and 4 other-than-serious.

Penalties were first proposed at $1,400 and now stand at $700, 50% lower after settlements or reviews.

Using electrical equipment comes up most often in these citations: 2 items under 1910.334.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and American Cargo Group averages $350 (2 cited inspections).

American Cargo Group: OSHA citation items per year, 2021 to 2025
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch American Cargo Group and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347975120 OPENED JAN 10, 2025Closed

Accident · Partial · Safety · 147 employees at the site · Closed Feb 13, 2025

1741 W 2550 S, Ogden, UT 84401 · Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR UAC R614-1-5.D.5
Other-than-serious$0$0Jan 28, 2025Final

Inspection 345170252 OPENED FEB 26, 2021Closed

Complaint · Partial · Safety · 200 employees at the site · Closed Mar 25, 2021

1741 W 2550 S, Ogden, UT 84401 · Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,400$700Mar 18, 2021Final
Citation 1, item 2a
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Other-than-serious$0$0Mar 18, 2021Final
Citation 1, item 2b
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Mar 18, 2021Final
Citation 1, item 2c
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Mar 18, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(x)

(x) Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.