OSHA SearchOSHA records by employer

American Lighting & Signalization: OSHA inspections and violations

Coleman, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
1citation items
$7,000current penalties
Oct 12, 2017last inspection

American Lighting & Signalization has one OSHA inspection on record in Texas.

OSHA opened it on Oct 12, 2017 on a referral, in Coleman.

From that inspection OSHA issued 1 citation item: 1 other-than-serious.

OSHA proposed $12,934 in penalties. After settlements and reviews the total is $7,000, down 46%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. American Lighting & Signalization averages $7,000 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

American Lighting & Signalization: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch American Lighting & Signalization and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342696531 OPENED OCT 12, 2017Closed

Referral · Partial · Safety · 10 employees at the site · Closed Feb 23, 2018

Sh183 And Colorado St, Coleman, TX 76834 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 4, 2017: Employee testing street light is shocked and burned

At 3:20 p.m. on October 4, 2017, Employee #1, employed by a street lighting and safety services company, was performing diagnostics on a street light when he received an electrical shock. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for electrical burns to both hands and abdomen, a dislocated shoulder, and facial bruising. bruising.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.333(c)(2) · Working near live electrical parts
Other-than-serious$12,934$7,000Jan 8, 2018Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 4, 2017, Coleman: Hospitalization · electrical burns, unspecified · multiple body parts, n.e.c.

While performing diagnostics on a street light pole, an employee received an electrical shock and burns on both hands, the abdomen, and the shoulders.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(2)

(2) Work on energized equipment. Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.