OSHA SearchOSHA records by employer

American Masonry LLC: OSHA inspections and violations

Revere, Massachusetts · Masonry Contractors · NAICS 238140

4inspections
14citation items
$6,710current penalties
Jun 10, 2016last inspection

American Masonry LLC has 4 OSHA inspections on record in Massachusetts, the first in 1985.

OSHA's last visit started on Jun 10, 2016 as a planned inspection, in Middleton.

Across those inspections OSHA issued 14 citation items: 12 serious and 2 other-than-serious.

OSHA proposed $9,510 in penalties. After settlements and reviews the total is $6,710, down 29%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. American Masonry LLC averages $2,000 over 1 cited inspection in that time.

American Masonry LLC: OSHA citation items per year, 1985 to 2016
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch American Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341542470 OPENED JUN 10, 2016Closed

Planned · Partial · Health · 3 employees at the site · Closed Feb 24, 2017

239 S. Main St., Middleton, MA 01949 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$2,400$1,000Jun 21, 2016Final
Citation 1, item 2a
29 CFR 1926.101(a) · Hearing protection
Serious$2,400$1,000Jun 21, 2016Final
Citation 1, item 2b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Jun 21, 2016Final

Inspection 109128074 OPENED OCT 19, 1993Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jun 20, 1995

46 Chauncy Street, Mansfield, MA 02048 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$875$875Oct 29, 1993Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$875$875Oct 29, 1993Closed
Citation 1, item 3
29 CFR 1926.500(b)(5) · Scope, application, and definitions applicable to this subpart
Serious$875$875Oct 29, 1993Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$875$875Oct 29, 1993Closed

Inspection 100981711 OPENED APR 10, 1990Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 28, 1991

Salem & Cross Streets, Boston, MA 02133 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$350$350Jun 28, 1990Closed
Citation 1, item 2
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Serious$350$350Jun 28, 1990Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$350$350Jun 28, 1990Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jun 28, 1990Closed

Inspection 100432368 OPENED OCT 11, 1985Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed May 30, 1986

255 Squire Road, Revere, MA 02151 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$80$80Nov 4, 1985Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$80$80Nov 4, 1985Closed
Citation 2, item 1
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Other-than-serious$0$0Nov 4, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.101 · Hearing protection

29 CFR 1926.101(a)

(a) Wherever it is not feasible to reduce the noise levels or duration of exposures to those specified in Table D-2, Permissible Noise Exposures, in § 1926.52, ear protective devices shall be provided and used.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.