Inspection 342231941 OPENED APR 4, 2017Closed
2000 S. Eads Street, Arlington, VA 22202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2014, OSHA inspectors have visited American Property Construction in Virginia 4 times.
The most recent inspection opened on Apr 4, 2017 after a complaint, in Arlington.
In all, OSHA issued 4 citation items: 4 serious.
The penalties, $1,680 in total, stand where OSHA first set them.
The rule cited most here is 1926.502 (fall protection systems), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. American Property Construction averages $1,680 across 1 cited inspection.
Virginia · latest 90 days of OSHA records
248employers cited
21 of them in the same industry
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch American Property Construction and get notified the morning OSHA posts a new citation for it.
Watch this company2000 S. Eads Street, Arlington, VA 22202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
700 North Washington Street, Alexandria, VA 22314 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $1,680 | $1,680 | Jan 18, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.502(b)(2)(i) · Fall protection systems |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 1, item 1c 29 CFR 1926.502(b)(4) · Fall protection systems |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 1, item 1d 29 CFR 1926.502(b)(9) · Fall protection systems |
Serious | $0 | $0 | Jan 18, 2017 | Final |
1900 Eads Street 2000 Eads Street, Arlington, VA 22202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1900 South Eads Street, Arlington, VA 22202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.502(b)(1)
(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.
29 CFR 1926.502(b)(2)(i)
(i) Midrails, when used, shall be installed at a height midway between the top edge of the guardrail system and the walking/working level.
29 CFR 1926.502(b)(4)
(4) When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section is applied in a downward direction, the top edge of the guardrail shall not deflect to a height less than 39 inches (1.0 m) above the walking/working level. Guardrail system components selected and constructed in accordance with the appendix B to subpart M of this part will be deemed to meet this requirement.