Inspection 347928475 OPENED DEC 6, 2024Closed
8275 Spring Mountain Road, Las Vegas, NV 89117 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1996, OSHA inspectors have visited American Southwest Electric in Nevada 8 times.
The most recent inspection opened on Dec 6, 2024 on a referral, in Las Vegas.
In all, OSHA issued 18 citation items: 12 serious and 6 other-than-serious.
The proposed penalties came to $80,623; today they stand at $58,927, 27% less.
The rule cited most here is 1910.134 (respiratory protection), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. American Southwest Electric averages $26,888 across 2 cited inspections.
1 inspection on this page followed a fatal incident.
American Southwest Electric also files yearly injury logs with OSHA, summarized below.
Nevada · latest 90 days of OSHA records
110employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Nevada
Checking a subcontractor, a client or your own company? Watch American Southwest Electric and get notified the morning OSHA posts a new citation for it.
Watch this company8275 Spring Mountain Road, Las Vegas, NV 89117 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 St. Jude's Street, Boulder City, NV 89005 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6161 West Charleston Boulevard, Las Vegas, NV 89146 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
| Citation 1, item 4 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
| Citation 1, item 5 29 CFR 1926.1153(c)(1) · Silica dust in construction |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
| Citation 1, item 6 29 CFR 1926.1153(d)(2)(i) · Silica dust in construction |
Serious | $7,232 | $3,616 | May 17, 2023 | Final |
4949 East Cheyenne Avenue, Las Vegas, NV 89115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Sep 1, 2022 (fatal): Employee dies after being electrocuted while stripping wire
At 10:30 a.m. on September 1, 2022, an employee was preparing to connect soccer field lightning to an electrical panel. While the employee was stripping a live wire (277 volt, 30 amp), his right middle finger made contact with the wire and he was electrocuted. The employee was transported to the hospital and died later that day.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(h) · Electrical equipment on job sites |
Serious | $10,151 | $10,151 | Feb 23, 2023 | Contested |
| Citation 1, item 2 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $10,151 | $10,151 | Feb 23, 2023 | Contested |
| Citation 1, item 3 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $10,151 | $10,151 | Feb 23, 2023 | Contested |
| Citation 2, item 1 29 CFR NEVADA REVISED STATUTES 618.383(1 |
Other-than-serious | $814 | $814 | Feb 23, 2023 | Contested |
| Citation 2, item 2 29 CFR NEVADA ADMINISTRATIVE CODE 618.54 |
Other-than-serious | $814 | $814 | Feb 23, 2023 | Contested |
300 South Racetrack Road, Henderson, NV 89015 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $150 | $150 | Jul 15, 2009 | Closed |
8475 South Eastern, Las Vegas, NV 89123 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $0 | $0 | Apr 13, 2001 | Closed |
| Citation 1, item 2 | Other-than-serious | $0 | $0 | Apr 13, 2001 | Closed |
8475 South Eastern, Las Vegas, NV 89123 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
657 Town Center Drive, Las Vegas, NV 89144 · OSHA's record · Phone and website on Google Maps
Incident on Apr 11, 1996: Electric shock & fall - cause unknown
An electrician received an electric shock while he was working. The electric sho ck caused him to fall from an elevated location. He was hospitalized for his inj uries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $2,500 | $2,500 | Jul 19, 1996 | Closed |
| Citation 1, item 1b 29 CFR 1926.417(d)(1) · Lockout and tagging of circuits |
Serious | $0 | $0 | Jul 19, 1996 | Closed |
| Citation 1, item 2 29 CFR 1926.417(d)(4)(ii) · Lockout and tagging of circuits |
Serious | $2,500 | $2,500 | Jul 19, 1996 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | May 15, 1996 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Las Vegas site logged 1 recordable injury or illness among about 264 workers: 0.9 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| American Southwest Electric Las Vegas · 2023 | 264 | 1 | 0 | 0.9 | 1.8 |
Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.134(f)(1)
(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.
Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.