OSHA SearchOSHA records by employer

American Utility Processing, LLC: OSHA inspections and violations

Akron, Ohio · Aluminum Sheet, Plate, and Foil Manufacturing · NAICS 331315

2inspections
5citation items
$7,988current penalties
Feb 8, 2021last inspection

OSHA has inspected American Utility Processing, LLC 2 times in Ohio since 2012.

The latest one began on Feb 8, 2021 after a complaint, in Akron.

Those inspections ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $12,962 and now stand at $7,988, 38% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and American Utility Processing, LLC averages $6,560 (1 cited inspection).

American Utility Processing, LLC: OSHA citation items per year, 2012 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites American Utility Processing, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345139075 OPENED FEB 8, 2021Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Apr 1, 2022

1246 Princeton St., Akron, OH 44301 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$5,461$3,280Apr 21, 2021Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,461$3,280Apr 21, 2021Final

Inspection 332814995 OPENED MAR 13, 2012Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Apr 23, 2012

1246 Princeton St., Akron, OH 44301 · Aluminum Sheet, Plate, and Foil Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,040$1,428Mar 28, 2012Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 28, 2012Final
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 28, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

Other aluminum sheet, plate, and foil manufacturing employers in Ohio