OSHA SearchOSHA records by employer

Americana Contracting Corp: OSHA inspections and violations

Brooklyn, New York · Masonry Contractors · NAICS 238140

1inspections
4citation items
$16,200current penalties
Nov 7, 2024last inspection

Americana Contracting Corp has one OSHA inspection on record in New York.

OSHA opened it on Nov 7, 2024 on a referral, in Brooklyn, and the case has not closed yet.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $25,535 in penalties. After settlements and reviews the total is $16,200, down 37%.

Most often, OSHA cited 1926.502, fall protection systems (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Americana Contracting Corp averages $16,200 over 1 cited inspection in that time.

Americana Contracting Corp: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

358employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Americana Contracting Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347866337 OPENED NOV 7, 2024Open

Referral · Partial · Safety · 2 employees at the site · Open

1751 85th Street, Brooklyn, NY 11214 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(5)(iii) · Scaffolds, general requirements
Serious$6,620$4,050May 2, 2025Final
Citation 1, item 2
29 CFR 1926.502(d)(11) · Fall protection systems
Serious$6,620$4,050May 2, 2025Final
Citation 1, item 3
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$6,620$4,050May 2, 2025Final
Citation 1, item 4
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$5,675$4,050May 2, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(5)(iii)

(iii) Secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks shall be installed and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)(11)

(11) Lifelines shall be protected against being cut or abraded.

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.