Inspection 349259341 OPENED OCT 31, 2026Open
700 Conroe Park N. Drive, Conroe, TX 77303 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2021, OSHA inspectors have visited Ameritex Machine and Fabrication, LLC in Texas 2 times.
The most recent inspection opened on Oct 31, 2026 after a fatality or catastrophe, in Conroe and is still open.
In all, OSHA issued 1 citation item: 1 other-than-serious.
The proposed penalties came to $6,144; today they stand at $3,072, 50% less.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Ameritex Machine and Fabrication, LLC averages $3,072 across 1 cited inspection.
The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.
Texas · latest 90 days of OSHA records
399employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Ameritex Machine and Fabrication, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company700 Conroe Park N. Drive, Conroe, TX 77303 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
13391 East Fm 1097 Road, Willis, TX 77378 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.254(b)(4)(iv) · Arc welding and cutting |
Other-than-serious | $6,144 | $3,072 | Jun 23, 2021 | Final |
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Feb 22, 2014 to Feb 20, 2016 Willis | 2 | 0 | $0 | $3,100 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.254(b)(4)(iv)
(iv) Terminals for welding leads should be protected from accidental electrical contact by personnel or by metal objects, i.e., vehicles, crane hooks, etc. Protection may be obtained by use of: Dead-front receptacles for plug connections; recessed openings with nonremovable hinged covers; heavy insulating sleeving or taping or other equivalent electrical and mechanical protection. If a welding lead terminal which is intended to be used exclusively for connection to the work is connected to the grounded enclosure, it must be done by a conductor at least two AWG sizes smaller than the grounding conductor and the terminal shall be marked to indicate that it is grounded.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.