OSHA SearchOSHA records by employer

Ameriwood Industries Inc dba Dorel Home Furnishings: OSHA inspections and violations

Dowagiac, Michigan · Nonupholstered Wood Household Furniture Manufacturing · NAICS 337122

2inspections
12citation items
$6,550current penalties
Feb 14, 2022last inspection

Ameriwood Industries Inc dba Dorel Home Furnishings has 2 OSHA inspections on record in Michigan, the first in 2019.

OSHA's last visit started on Feb 14, 2022 as a planned inspection, in Dowagiac.

Across those inspections OSHA issued 12 citation items: 7 serious and 5 other-than-serious.

OSHA proposed $13,100 in penalties. After settlements and reviews the total is $6,550, down 50%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Ameriwood Industries Inc dba Dorel Home Furnishings averages $6,550 over 1 cited inspection in that time.

Ameriwood Industries Inc dba Dorel Home Furnishings: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

621employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Ameriwood Industries Inc dba Dorel Home Furnishings and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345782320 OPENED FEB 14, 2022Closed

Planned · Complete · Safety · 15 employees at the site · Closed Feb 23, 2022

202 Spaulding St, Dowagiac, MI 49047 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344470802 OPENED NOV 25, 2019Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jan 28, 2020

202 Spaulding St, Dowagiac, MI 49047 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(3)
Serious$900$450Dec 19, 2019Final
Citation 1, item 2
29 CFR 408.10187(1)
Serious$900$450Dec 19, 2019Final
Citation 1, item 3
29 CFR 408.12759(2)
Serious$1,200$600Dec 19, 2019Final
Citation 1, item 4
29 CFR 408.12759(1)
Serious$1,200$600Dec 19, 2019Final
Citation 1, item 5
29 CFR 408.12717
Serious$4,200$2,100Dec 19, 2019Final
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,200$600Dec 19, 2019Final
Citation 1, item 7
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,500$1,750Dec 19, 2019Final
Citation 2, item 1a
29 CFR 408.11222(1)
Other-than-serious$0$0Dec 19, 2019Final
Citation 2, item 1b
29 CFR 408.11223(1)
Other-than-serious$0$0Dec 19, 2019Final
Citation 2, item 2
29 CFR 408.11411(2)
Other-than-serious$0$0Dec 19, 2019Final
Citation 2, item 3
29 CFR 408.12176(1)
Other-than-serious$0$0Dec 19, 2019Final
Citation 2, item 4
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Dec 19, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: