Amphenol Corporation: OSHA inspections and violations
Janesville, Wisconsin · Other Measuring and Controlling Device Manufacturing · NAICS 334519
1inspections
3citation items
$14,528current penalties
Nov 2, 2022last inspection
OSHA has inspected Amphenol Corporation once in Wisconsin.
The inspection began on Nov 2, 2022 after a complaint, in Janesville.
That inspection ended with 3 citation items: 3 serious.
Penalties were first proposed at $24,862 and now stand at $14,528, 42% lower after settlements or reviews.
Gas welding and cutting comes up most often in these citations: 2 items under 1910.253.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Amphenol Corporation averages $14,528 (1 cited inspection).
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
229employers cited
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
OSHA records show Amphenol Corporation at 2 sites in 2 states. Together they've had 12 inspections and $27,683 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.
(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.
29 CFR 1910.253(b)(2)(iv)
(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.