OSHA SearchOSHA records by employer

Ams Services & Designs, Inc: OSHA inspections and violations

Ellicott City, Maryland · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
2citation items
$687current penalties
Apr 11, 2017last inspection

OSHA inspectors have visited Ams Services & Designs, Inc in Maryland one time.

It opened on Apr 11, 2017 after an accident, in Ellicott City.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $687 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ams Services & Designs, Inc averages $687 across 1 cited inspection.

Ams Services & Designs, Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Ams Services & Designs, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342242021 OPENED APR 11, 2017Closed

Accident · Complete · Safety · 5 employees at the site · Closed May 19, 2017

9200 Baltimore National Pike, Suite D, Ellicott City, MD 21042 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 10, 2017: Worker steadying ladder is struck and is injured by falling

At 2:30 p.m. on April 10, 2017, Employee #1 and Coworker #1, employed by a construction subcontractor at a multiemployer construction project for a commercial building, were removing a light fixture from a roof joist. Employee #1 was standing at the base of a Werner 10-foot A-Frame ladder and steadying it. Coworker #1 was standing on the ladder's top step and reaching up to a height as great as 16 feet to disconnect the 30-pound temporary halogen light fixture. Coworker #1 disconnected the light fixture, but then lost control of the fixture. The fixture fell, first striking a ceiling tile framing 9 feet above a concrete floor and then continuing to fall and striking Employee #1. The light fixture fell approximately 16 feet before striking Employee #1. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for bruises, contusions, and possible nerve damage to the left shoulder and lower neck area.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$312$312Apr 25, 2017Final
Citation 1, item 2
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$375$375Apr 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

Other electrical contractors and other wiring installation contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.