OSHA SearchOSHA records by employer

Anamet Electrical, Inc.: OSHA inspections and violations

Mattoon, Illinois · Current-Carrying Wiring Device Manufacturing · NAICS 335931

2inspections
3citation items
$15,809current penalties
Jun 6, 2025last inspection

OSHA has inspected Anamet Electrical, Inc. 2 times in Illinois since 2012.

The latest one began on Jun 6, 2025 on a referral, in Mattoon.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $15,809 and still stand at $15,809.

Machine guarding comes up most often in these citations: 2 items under 1910.212.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Anamet Electrical, Inc. averages $6,809 (1 cited inspection).

Anamet Electrical, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

The Wage and Hour Division has 1 case on it since 2015, with $4,311 in back wages owed to workers.

Anamet Electrical, Inc.: OSHA citation items per year, 2012 to 2025
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

423employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Anamet Electrical, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348296484 OPENED JUN 6, 2025Closed

Referral · Partial · Safety · 120 employees at the site · Closed Oct 17, 2025

1000 Broadway Avenue East, Mattoon, IL 61938 · Noncurrent-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$6,809$6,809Sep 25, 2025Final

Inspection 335036588 OPENED JUL 5, 2012Closed

Planned · Partial · Safety · 124 employees at the site · Closed Nov 21, 2012

1000 Broadway Avenue East, Mattoon, IL 61938 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,500$4,500Sep 24, 2012Final
Citation 2, item 1
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$4,500$4,500Sep 24, 2012Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mattoon site logged 11 recordable injuries or illnesses among about 122 workers: 9.1 per 100 full-time workers, against a median of 1.5 for its industry. Those cases cost 237 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Anamet Electrical, Inc
Mattoon · 2025
122 1159.11.5

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 4, 2025, Mattoon: Hospitalization · cuts, lacerations, punctures without injury to internal structures · elbow(s)

On June 4, 2025, an employee was starting up the rotary winding machine and breaking off a piece of conduit when his left arm was struck by a moving part. The employee was hospitalized with a severe laceration to the elbow that exposed the tendon and the joint.

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Oct 23, 2016 to Oct 22, 2018
Mattoon
1313$4,311$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(c)(2)(i)

(2) Guarding horizontal shafting. (i) All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.

Other current-carrying wiring device manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.