OSHA SearchOSHA records by employer

Ank Construction Inc: OSHA inspections and violations

Mechanicsville, Virginia · Framing Contractors · NAICS 238130

8inspections
14citation items
$5,496current penalties
Mar 1, 2022last inspection

Since 2008, OSHA inspectors have visited Ank Construction Inc in Virginia 8 times.

The most recent inspection opened on Mar 1, 2022 as a planned inspection, in Richmond.

In all, OSHA issued 14 citation items: 12 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $6,435; today they stand at $5,496, 15% less.

The rule cited most here is 1926.501 (fall protection in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Ank Construction Inc averages $1,480 across 2 cited inspections.

Ank Construction Inc: OSHA citation items per year, 2008 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Ank Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345811525 OPENED MAR 1, 2022Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jun 6, 2022

3934 Grove Point Dr., Richmond, VA 23223 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$865$606Apr 6, 2022Final
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$600$420Apr 6, 2022Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Apr 6, 2022Final

Inspection 341455129 OPENED APR 30, 2016Closed

Planned · Partial · Safety · 5 employees at the site · Closed Aug 19, 2016

Lot Number 2009 Windy Creek Terrace, Chesterfield, VA 23832 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$495$495Jun 22, 2016Final
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$720$720Jun 22, 2016Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$720$720Jun 22, 2016Final

Inspection 341011427 OPENED OCT 21, 2015Closed

Planned · Partial · Safety · 11 employees at the site · Closed Oct 28, 2015

Intersection Of Compass Point Lane And Washington Arch Drive Liberty Trace Lots 160-161, Mechanicsville, VA 23111 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317383362 OPENED NOV 18, 2013Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Dec 5, 2013

7901-7885 Marshall Arch Drive, Liberty Trace Townh, Mechanicsville, VA 23111 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316474196 OPENED MAR 16, 2012Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 5, 2012

5105 Hungary Branch Court, Glen Allen, VA 23058 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$315$315May 22, 2012Closed
Citation 1, item 2a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$420$420May 22, 2012Closed
Citation 1, item 2b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0May 22, 2012Closed
Citation 1, item 2c
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0May 22, 2012Closed
Citation 1, item 2d
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0May 22, 2012Closed
Citation 1, item 2e
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0May 22, 2012Closed

Inspection 314718412 OPENED JUL 20, 2010Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 22, 2010

Lot 1 K New Market Valley Parkway, Richmond, VA 23231 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313712283 OPENED AUG 12, 2009Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jun 25, 2010

Spring Ridge & Swift Creek, Spring Ridge Ct Lot 27, Midlothian, VA 23112 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$2,000$1,500Sep 8, 2009Closed

Inspection 312564651 OPENED SEP 10, 2008Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Nov 17, 2008

7293-7297 Jackson Arch Dr, Liberty Trace Townhomes, Mechanicsville, VA 23111 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$300$300Sep 24, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Virginia