OSHA SearchOSHA records by employer

Anr Development Co.,Inc.: OSHA inspections and violations

Easton, Pennsylvania · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
8citation items
$18,234current penalties
Nov 29, 2023last inspection

OSHA has inspected Anr Development Co.,Inc. 4 times in Pennsylvania since 2019.

The latest one began on Nov 29, 2023 after a complaint, in Easton.

Those inspections ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $28,070 and now stand at $18,234, 35% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Anr Development Co.,Inc. averages $4,559 (4 cited inspections).

Anr Development Co.,Inc.: OSHA citation items per year, 2019 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Anr Development Co.,Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347129744 OPENED NOV 29, 2023Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Aug 18, 2025

40 South 6th St., Easton, PA 18042 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$5,071$3,043May 24, 2024Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$5,071$3,043May 24, 2024Final

Inspection 346742703 OPENED JUN 2, 2023Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Feb 25, 2025

34-42 S. 6th Street, Easton, PA 18042 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(j)(1) · Excavations
Serious$6,250$4,375Nov 13, 2023Final
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Nov 13, 2023Final

Inspection 344536842 OPENED JAN 3, 2020Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jan 11, 2021

West Drive, Center Valley, PA 18034 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$2,545$2,000Jan 27, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$2,313$1,000Jan 27, 2020Final

Inspection 343696340 OPENED JAN 7, 2019Closed

Referral · Partial · Safety · 6 employees at the site · Closed Jan 21, 2020

623-629 Walnut Avenue, Easton, PA 18042 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$2,955Feb 19, 2019Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,842$1,819Feb 19, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other new single-family housing construction (except for-sale builders) employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.