OSHA SearchOSHA records by employer

Antonio Castillo: OSHA inspections and violations

Dacula, Georgia · Masonry Contractors · NAICS 238140

1inspections
5citation items
$11,175current penalties
Jun 8, 2017last inspection

OSHA inspectors have visited Antonio Castillo in Georgia one time.

It opened on Jun 8, 2017, in Dacula.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The penalties, $11,175 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Antonio Castillo averages $11,175 across 1 cited inspection.

Antonio Castillo: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Antonio Castillo again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342391349 OPENED JUN 8, 2017Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jan 11, 2022

3450 Braselton Hwy, Dacula, GA 30019 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$2,716$2,716Sep 28, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,716$2,716Sep 28, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,716$2,716Sep 28, 2017Final
Citation 1, item 4
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$2,716$2,716Sep 28, 2017Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$311$311Apr 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Georgia