OSHA SearchOSHA records by employer

Antonio Lopez Martinez: OSHA inspections and violations

Josephine, Texas · Framing Contractors · NAICS 238130

1inspections
3citation items
$12,055current penalties
Jul 21, 2023last inspection

OSHA has inspected Antonio Lopez Martinez once in Texas.

The inspection began on Jul 21, 2023 as a planned inspection, in Josephine.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $12,055 and still stand at $12,055.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Antonio Lopez Martinez averages $12,055 (1 cited inspection).

Antonio Lopez Martinez: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Antonio Lopez Martinez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346859093 OPENED JUL 21, 2023Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 9, 2026

415 Mcdonald Dr, Josephine, TX 75173 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$4,688$4,688Oct 25, 2023Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$2,679$2,679Oct 25, 2023Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$4,688Oct 25, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.