Antrim Masonry Corp.: OSHA inspections and violations

Norwalk, Connecticut · Masonry Contractors · NAICS 238140

1inspections
5citation items
$5,741current penalties
Nov 3, 2017last inspection

Antrim Masonry Corp. has one OSHA inspection on record in Connecticut.

OSHA opened it on Nov 3, 2017 as part of a related case, in Norwalk.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $8,202 in penalties. After settlements and reviews the total is $5,741, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Antrim Masonry Corp. averages $5,741 over 1 cited inspection in that time.

Antrim Masonry Corp.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

83employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Antrim Masonry Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342767787 OPENED NOV 3, 2017Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Aug 25, 2022

41-47 S Main Street, Norwalk, CT 06854 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$3,259$2,281Dec 27, 2017Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Dec 27, 2017Final
Citation 1, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,173$1,521Dec 27, 2017Final
Citation 1, item 2b
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Dec 27, 2017Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,770$1,939Dec 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(8)

(8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.