OSHA SearchOSHA records by employer

Apache Electric: OSHA inspections and violations

Las Vegas, Nevada · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
3citation items
$1,450current penalties
May 8, 2015last inspection

Since 2008, OSHA inspectors have visited Apache Electric in Nevada 3 times.

The most recent inspection opened on May 8, 2015 after a fatality or catastrophe, in Las Vegas.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $1,450 in total, stand where OSHA first set them.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Apache Electric averages $1,450 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Apache Electric: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Apache Electric again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340621580 OPENED MAY 8, 2015Closed

Fatality or catastrophe · Partial · Safety · 11 employees at the site · Closed Oct 28, 2015

7294 Durand Park Street, Las Vegas, NV 89166 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 8, 2015 (fatal): Employee is crushed by retaining wall collapsing into trench

At 1:40 p.m. on May 8, 2015, an employee was placing 3 inch PVC conduit in an excavated trench. The excavation exposed one side of a retaining wall and its footing, which ran parallel to the trench. A 4 X 6 inch wooden board was placed in under the exposed footing and wedged up against the opposite embankment to support the retaining wall from collapsing. The employee removed the wooden support and the wall collapsed into the trench, pinning the employee against the adjacent trench wall. The employee suffered fatal blunt force trauma injuries to the chest and minor abrasions to the head.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$600$600Jul 31, 2015Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$600$600Jul 31, 2015Final
Citation 1, item 3
29 CFR 1926.651(i)(1) · Excavations
Serious$250$250Jul 31, 2015Final

Inspection 313974990 OPENED JUN 9, 2010Closed

Referral · Partial · Health · 10 employees at the site · Closed Jun 9, 2010

4300 North Pecos Road, #25, Las Vegas, NV 89115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312275217 OPENED JUL 7, 2008Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jul 28, 2008

4300 North Pecos Road, #25, Las Vegas, NV 89115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other electrical contractors and other wiring installation contractors employers in Nevada

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.