OSHA SearchOSHA records by employer

Apex Anodizing (Nev), Inc.: OSHA inspections and violations

Sparks, Nevada · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

2inspections
4citation items
$2,785current penalties
Sep 30, 2019last inspection

Apex Anodizing (Nev), Inc. has 2 OSHA inspections on record in Nevada, the first in 2019.

OSHA's last visit started on Sep 30, 2019 as a planned inspection, in Sparks.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $3,978 in penalties. After settlements and reviews the total is $2,785, down 30%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Apex Anodizing (Nev), Inc. averages $1,392 over 2 cited inspections in that time.

Apex Anodizing (Nev), Inc. also files yearly injury logs with OSHA, summarized below.

Apex Anodizing (Nev), Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Apex Anodizing (Nev), Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344343835 OPENED SEP 30, 2019Closed

Planned · Complete · Safety · 17 employees at the site · Closed Jan 2, 2020

280 Coney Island Ste B, Sparks, NV 89431 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$1,224$857Dec 11, 2019Final
Citation 1, item 2
29 CFR NEVADA REVISED STATUTES 618.375(1
Serious$1,224$857Dec 11, 2019Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Dec 11, 2019Final

Inspection 344348487 OPENED SEP 30, 2019Closed

Planned · Complete · Health · 17 employees at the site · Closed Jan 2, 2020

280 Coney Island Ste B, Sparks, NV 89431 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,530$1,071Dec 11, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Sparks site logged 1 recordable injury or illness among about 19 workers: 4.8 per 100 full-time workers, against a median of 3.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Apex Anodizing
Sparks · 2022
19 104.83.2

Included with any plan: 1 more yearly log from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(1)(iv)(a)

(A) As a substitute for the fixed wiring of a structure;

Other electroplating, plating, polishing, anodizing, and coloring employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.