Somerset, New Jersey · Pharmaceutical Preparation Manufacturing · NAICS 325412
1inspections
7citation items
$6,860current penalties
Aug 24, 2015last inspection
Apicore US LLC has one OSHA inspection on record in New Jersey.
OSHA opened it on Aug 24, 2015 after a complaint, in Somerset.
From that inspection OSHA issued 7 citation items: 6 serious and 1 other-than-serious.
OSHA proposed $9,800 in penalties. After settlements and reviews the total is $6,860, down 30%.
Most often, OSHA cited 1910.134, respiratory protection (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Apicore US LLC averages $6,860 over 1 cited inspection in that time.
Apicore US LLC also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New Jersey · latest 90 days of OSHA records
269employers cited
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Somerset site logged 0 recordable injuries or illnesses among about 32 workers: 0.0 per 100 full-time workers, against a median of 0.6 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Apicore US LLC
Somerset · 2022
32
0
0
0.0
0.6
Apicore
Somerset · 2017
65
0
0
0.0
0.0
Included with any plan: 4 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.