Apollo Builders: OSHA inspections and violations

Brooklyn, New York · Residential Remodelers · NAICS 236118

1inspections
4citation items
$4,900current penalties
Apr 23, 2015last inspection

OSHA inspectors have visited Apollo Builders in New York one time.

It opened on Apr 23, 2015 after a complaint, in Brooklyn.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $9,200; today they stand at $4,900, 47% less.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Apollo Builders averages $4,900 across 1 cited inspection.

Apollo Builders: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Apollo Builders again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340581495 OPENED APR 23, 2015Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Aug 1, 2017

160 Prospect Park West, Brooklyn, NY 11215 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(h)(1) · Woodworking tools
Serious$2,800$1,850Oct 21, 2015Final
Citation 1, item 3
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Other-than-serious$1,600$1,200Oct 21, 2015Final
Citation 1, item 5a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,000$1,850Oct 21, 2015Final
Citation 1, item 5b
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$2,800$0Oct 21, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(h)(1)

(h) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(e)

(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.