OSHA SearchOSHA records by employer

Aptus Group USA LLC: OSHA inspections and violations

Portsmouth, Virginia · Highway, Street, and Bridge Construction · NAICS 237310

1inspections
8citation items
$17,504current penalties
Jun 17, 2021last inspection

Aptus Group USA LLC has one OSHA inspection on record in Virginia.

OSHA opened it on Jun 17, 2021 after a fatality or catastrophe, in Portsmouth.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $25,005 in penalties. After settlements and reviews the total is $17,504, down 30%.

Most often, OSHA cited 1926.405, job-site wiring (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Aptus Group USA LLC averages $17,504 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Aptus Group USA LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Aptus Group USA LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345411409 OPENED JUN 17, 2021Closed

Fatality or catastrophe · Partial · Safety · 8 employees at the site · Closed Jan 28, 2022

State Highway 164 East, On Outside Shoulder Between The West Norfolk Road Exit And On-ramp., Portsmouth, VA 23703 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 16, 2021 (fatal): Employee is struck and killed by pickup truck

At 5:30 a.m. on June 16, 2021, an employee assisted a coworker to clean up traffic cones and signage to reopen a lane closure. The coworker operated a Pickup truck (Dodge Diesel 55 Pickup Truck Crew Cab) in reverse down the highway as the employee picked up traffic cones. The coworker stopped the pickup briefly to verify the location of two cones, re-entered the pickup and continued to operate the vehicle in reverse. Meanwhile, the employee attempted to cross behind the pickup, going from the rear, passenger side to the rear, driver's side of the truck. The employee was struck by the rear bumper, knocked to the ground, and then run over by the truck and killed due to crushing injuries to the upper body and head.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 40.1-51.1.A
Serious$9,295$6,506Dec 10, 2021Final
Citation 1, item 2a
29 CFR 16VAC25-97-30.A.1
Serious$7,855$5,498Dec 10, 2021Final
Citation 1, item 2b
29 CFR 16VAC25-97-50.A
Serious$0$0Dec 10, 2021Final
Citation 1, item 3a
29 CFR 1926.405(d) · Job-site wiring
Serious$7,855$5,498Dec 10, 2021Final
Citation 1, item 3b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Dec 10, 2021Final
Citation 1, item 3c
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$0$0Dec 10, 2021Final
Citation 1, item 3d
29 CFR 1926.405(j)(2)(ii) · Job-site wiring
Serious$0$0Dec 10, 2021Final
Citation 1, item 3e
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Dec 10, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.

29 CFR 1926.416 · Electrical safety in construction

Other highway, street, and bridge construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.