OSHA SearchOSHA records by employer

Apx Mitchell Machine Shop: OSHA inspections and violations

Greencastle, Pennsylvania · Machine Shops · NAICS 332710

1inspections
5citation items
$3,389current penalties
Feb 1, 2018last inspection

OSHA inspectors have visited Apx Mitchell Machine Shop in Pennsylvania one time.

It opened on Feb 1, 2018 after a complaint, in Greencastle.

In all, OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

The proposed penalties came to $4,841; today they stand at $3,389, 30% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Apx Mitchell Machine Shop averages $3,389 across 1 cited inspection.

Apx Mitchell Machine Shop also files yearly injury logs with OSHA, summarized below.

Apx Mitchell Machine Shop: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Apx Mitchell Machine Shop and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342920014 OPENED FEB 1, 2018Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Mar 28, 2018

550 South Molly Pitcher Highway, Greencastle, PA 17225 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(h)(1) · Belts, pulleys and power-transmission parts
Serious$2,956$2,069Feb 22, 2018Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$1,885$1,320Feb 22, 2018Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Feb 22, 2018Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 22, 2018Final
Citation 2, item 3
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Feb 22, 2018Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Greencastle site logged 1 recordable injury or illness among about 10 workers: 10.4 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
APX Mitchell Machine Shop, Inc.
Greencastle · 2025
10 1010.42.7
APX Mitchell Machine Shop
Greencastle · 2023
12 000.02.7

Included with any plan: 4 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(h)(1)

(h) Keys, setscrews, and other projections. (1) All projecting keys, setscrews, and other projections in revolving parts shall be removed or made flush or guarded by metal cover. This subparagraph does not apply to keys or setscrews within gear or sprocket casings or other enclosures, nor to keys, setscrews, or oilcups in hubs of pulleys less than twenty (20) inches in diameter where they are within the plane of the rim of the pulley.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other machine shops employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.