Since 2023, OSHA inspectors have visited Aquafil O'Mara, Inc. in North Carolina 3 times.
The most recent inspection opened on Oct 27, 2023 on a referral, in Rutherford College.
In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.
The proposed penalties came to $8,450; today they stand at $5,900, 30% less.
The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Aquafil O'Mara, Inc. averages $2,950 across 2 cited inspections.
Aquafil O'Mara, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
North Carolina · latest 90 days of OSHA records
228employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Rutherford College site logged 5 recordable injuries or illnesses among about 144 workers: 3.3 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 35 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Aquafil OMara
Rutherford College · 2025
144
5
1
3.3
2.1
Aquafil O'Mara
Rutherford College · 2022
140
4
0
2.3
2.1
Included with any plan: 2 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.219 · Belts, pulleys and power-transmission parts
29 CFR 1910.219(c)(3)
(3) Guarding vertical and inclined shafting. Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section.
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(b)(7)(i)
(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.
29 CFR 1910.303(e)(1)(ii)
(ii) Other markings giving voltage, current, wattage, or other ratings as necessary.
Other fiber, yarn, and thread mills employers in North Carolina
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.